Welded Joints
A simple and easy to perform quality test is based on the shear force. Evaluations of welding assemblies in electrical performance tests have shown
however, that the shear force is only a valid measure if combined with the size of the welded area. As rule of thumb, the shear force should be > 100 N/mm with the welded area > 60% of the original wire or profile cross-sectional area. For critical applications in power engineering, for example for high currents and/or high switching frequency, a higher percentage of the joint area is necessary.
During series production every weld is usually probed in a testing station integrated in the manufacturing line with a defined shear force – mostly 20% of the maximum achievable force. In this way defective welds and missing contacts can be found and sorted out. The monitoring of the actual shear force and size is performed during production runs, based on a sampling plan.
<figure id="fig:Ultrasonic picture of a weld">
[[File:Ultrasonic picture of a weld.jpg|right|thumb|Figure 3: Ultrasonic picture of a weld joint, Ag/C tip on Cu carrier (ABB-STOTZ-KONTAKT)]]
</figure>
Besides destructive testing for shear force and weld area, the non-destructive ultrasound testing of the joint quality is also utilized for welded contact assemblies (<xr id="fig:Ultrasonic picture of a weld"/><!--(Fig. 3.16)-->).