6.4.4 Switching Contacts
<xr id="fig:fig6.9"/> Fig. 6.9: Histogram of the contact resistance Rk of an electroplated palladium layer (3 μm) with and without hard gold flash plating (0.2 μm) after exposure with different plastic materials
<xr id="fig:fig6.10"/> Fig. 6.10: Contact resistance with exposure to out gasing from plasticsas a function of numbers of operations at 6 V<sub>DC</sub>,100 mA: 1 Silicon containing plastic; 2 Plastics with strongly out-gasing components; 3 Plastics with minimal out-gasing components