Difference between revisions of "General Rules for Dimensioning of Contacts"
From Electrical Contacts
								
												
				Doduco Admin (talk | contribs)  | 
				Doduco Admin (talk | contribs)   (→General Rules for Dimensioning of Contacts)  | 
				||
| Line 77: | Line 77: | ||
| + | '''Head diameter for electrical loads'''  | ||
| + | {| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"  | ||
| + | |-  | ||
| + | |For AC currents:       | ||
| + | |approx. 1 – 1.5 A/mm²  | ||
| + | |-  | ||
| + | |For 1 A     | ||
| + | |min. 2 mm head diameter  | ||
| + | |-  | ||
| + | |10 A    | ||
| + | |approx. 3 – 3.5 mm head diameter  | ||
| + | |-  | ||
| + | |20 A    | ||
| + | |approx. 5 mm head diameter  | ||
| + | |-  | ||
| + | |For DC currents:   | ||
| + | |approx. 0.5 – 0.8 A/mm²  | ||
| + | |}  | ||
| + | |||
| + | |||
| + | '''Head radius R for electrical loads'''  | ||
| + | |||
| + | {| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"  | ||
| + | |-  | ||
| + | |for I < 1 A       | ||
| + | |R ≈ 1,5 mm  | ||
| + | |-  | ||
| + | |I = 6 A      | ||
| + | |R ≈ 5 mm  | ||
| + | |-  | ||
| + | |I = 10 A      | ||
| + | |R ≈ 10 mm  | ||
| + | |-  | ||
| + | |I = 20 A      | ||
| + | |R ≈ 15 mm  | ||
| + | |}  | ||
Revision as of 08:45, 11 January 2023
General Rules for Dimensioning of Contacts
Recommended Minimum Contact Forces at Slightly Sliding Contact Make:
| Gold | 0.03 N | 
| Silver | 0.1 N | 
| Tungsten | 0.5 N | 
Contact Force Recommendations:
| Signal relays | ≥ 3 cN | 
| AC power relays | ≥ 20 cN | 
| Automotive relays | ≥ 20 cN | 
| Motor switches (Contactors) (Silver – Metal oxide contacts)  | 
0.05 - 0.08 N/A | 
| Power switches | 0.1 - 0.2 N/A | 
| Connectors (Gold coating)  | 
≥ 30 cN/contact element | 
| Connectors (Silver coating)  | 
≥ 50 cN/contact element | 
| Connectors (Tin coating)  | 
≥ 1 N/contact element | 
General Rules for Dimensioning of Contact Rivets
| Dimensioning | Solid Rivets (1) | Composite Rivets (2) | 
|---|---|---|
| a : d | 1.5 : 1 bis 2.5 : 1 | 2 : 1 bis 2.5 : 1 | 
| a : b | 2.5 : 1 bis 10 : 1 | 3 : 1 bis 5 : 1 | 
| c : b | ≥ 1 : 1 | ≥ 1 : 1 | 
| b : s | ≥ 2 : 1 | |
| smin | ≈ 0.3 mm | 
Head diameter for electrical loads
| For AC currents: | approx. 1 – 1.5 A/mm² | 
| For 1 A | min. 2 mm head diameter | 
| 10 A | approx. 3 – 3.5 mm head diameter | 
| 20 A | approx. 5 mm head diameter | 
| For DC currents: | approx. 0.5 – 0.8 A/mm² | 
Head radius R for electrical loads
| for I < 1 A | R ≈ 1,5 mm | 
| I = 6 A | R ≈ 5 mm | 
| I = 10 A | R ≈ 10 mm | 
| I = 20 A | R ≈ 15 mm | 
Failure Probability of Single and Double (Bifurcated) Contacts (according to Thielecke)
| Contact force[N] | Single contact | |||
|---|---|---|---|---|
| Ag | AuNi 5, Pt | Ag | AuNi 5, Pt | |
| 0.04 | 1 x 10-4 | 2 x 10-8 | ||
| 0.1 | 2 x 10-3 | 4 x 10-5 | 8 x 10-5 | 8 x 10-9 | 
| 0.2 | 1 x 10-4 | 8 x 10-6 | 4 x 10-6 | 4 x 10-8 | 
| 0.3 | 5.5 x 10-6 | 1.5 x 10-6 | 1.8 x 10-7 | 3.2 x 10-10 | 