Difference between revisions of "General Rules for Dimensioning of Contacts"

From Electrical Contacts
Jump to: navigation, search
(General Rules for Dimensioning of Contacts)
(General Rules for Dimensioning of Contacts)
Line 48: Line 48:
 
*'''General Rules for Dimensioning of Contact Rivets'''
 
*'''General Rules for Dimensioning of Contact Rivets'''
  
[[File:General Rules for Dimensioning of Contact Rivets.jpg|left|General Rules for Dimensioning of Contact Rivets]]
+
[[File:General Rules for Dimensioning of Contact Rivets.jpg|left|thumb|Figure 1: General Rules for Dimensioning of Contact Rivets]]
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
 
|-
 
|-
Line 157: Line 157:
 
<div class="multiple-images">
 
<div class="multiple-images">
 
<figure id="fig:Failure probability of a contact as a function of the voitage">
 
<figure id="fig:Failure probability of a contact as a function of the voitage">
[[File:Failure probability of a contact as a function of the voitage.jpg|left|thumb|Failure probability of a contact as a function of the voltage (according to Kirchdorfer); Ag/Ni10; 10 mA]]
+
[[File:Failure probability of a contact as a function of the voitage.jpg|left|thumb|Figure 2: Failure probability of a contact as a function of the voltage (according to Kirchdorfer); Ag/Ni10; 10 mA]]
 
</figure>
 
</figure>
  
 
<figure id="fig:Failure probability of a contact as a function of the current">
 
<figure id="fig:Failure probability of a contact as a function of the current">
[[File:Failure probability of a contact as a function of the current.jpg|left|thumb|Failure probability of a contact as a function of the current (according to Kirchdorfer); Ag/Ni10; F<sub>k</sub> = 0.45 N; U = 24 V]]
+
[[File:Failure probability of a contact as a function of the current.jpg|left|thumb|Figure 3: Failure probability of a contact as a function of the current (according to Kirchdorfer); Ag/Ni10; F<sub>k</sub> = 0.45 N; U = 24 V]]
 
</figure>
 
</figure>
 
</div>
 
</div>

Revision as of 14:33, 20 December 2022

General Rules for Dimensioning of Contacts

  • Recommended Minimum Contact Forces at Slightly Sliding Contact Make:
Gold 0.03 N
Silver 0.1 N
Tungsten 0.5 N
  • Contact Force Recommendations:
Signal relays ≥ 3 cN
AC power relays ≥ 20 cN
Automotive relays ≥ 20 cN
Motor switches (Contactors)
(Silver – Metal oxide contacts)
0.05 - 0.08 N/A
Power switches 0.1 - 0.2 N/A
Connectors
(Gold coating)
≥ 30 cN/contact element
Connectors
(Silver coating)
≥ 50 cN/contact element
Connectors
(Tin coating)
≥ 1 N/contact element


  • General Rules for Dimensioning of Contact Rivets
Figure 1: General Rules for Dimensioning of Contact Rivets
Dimensioning Solid Rivets (1) Composite Rivets (2)
a : d 1.5 : 1 bis 2.5 : 1 2 : 1 bis 2.5 : 1
a : b 2.5 : 1 bis 10 : 1 3 : 1 bis 5 : 1
c : b ≥ 1 : 1 ≥ 1 : 1
b : s ≥ 2 : 1
smin ≈ 0.3 mm


  • Head diameter for electrical loads
For AC currents: approx. 1 – 1.5 A/mm²
For 1 A min. 2 mm head diameter
10 A approx. 3 – 3.5 mm head diameter
20 A approx. 5 mm head diameter
For DC currents: approx. 0.5 – 0.8 A/mm²


  • Head radius R for electrical loads
for I < 1 A R ≈ 1,5 mm
I = 6 A R ≈ 5 mm
I = 10 A R ≈ 10 mm
I = 20 A R ≈ 15 mm


  • Failure Probability of Single and Double (Bifurcated) Contacts (according to Thielecke)
Contact force[N] Single contact
Ag AuNi 5, Pt Ag AuNi 5, Pt
0.04 1 x 10-4 2 x 10-8
0.1 2 x 10-3 4 x 10-5 8 x 10-5 8 x 10-9
0.2 1 x 10-4 8 x 10-6 4 x 10-6 4 x 10-8
0.3 5.5 x 10-6 1.5 x 10-6 1.8 x 10-7 3.2 x 10-10


Figure 2: Failure probability of a contact as a function of the voltage (according to Kirchdorfer); Ag/Ni10; 10 mA
Figure 3: Failure probability of a contact as a function of the current (according to Kirchdorfer); Ag/Ni10; Fk = 0.45 N; U = 24 V

References

References