*'''General Rules for Dimensioning of Contact RivetsFaustregeln zur Dimensionierung von Kontaktnieten'''
[[File:General Rules for Dimensioning of Contact Rivets.jpg|left|General Rules for Dimensioning of Contact RivetsFaustregeln zur Dimensionierung von Kontaktnieten]]
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
|-
!DimensioningDimensionierung!Solid Rivets Massivniet (1)!Composite Rivets Bimetallniet (2)
|-
|a : d
*'''Head diameter for electrical loadsKopfdurchmesser bei elektrischer Belastung'''
{| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"
|-
|For AC currentsbei Wechselstrom: |approxca. 1 – 1.5 A/mm²
|-
|For für 1 A |min. 2 mm head diameterKopfdurchmesser
|-
|10 A
|approxca. 3 – 3.5 mm head diameterKopfdurchmesser
|-
|20 A
|approxca. 5 mm head diameterKopfdurchmesser
|-
|For DC currentsbei Gleichstrom: |approxca. 0.5 – 0.8 A/mm²
|}
*'''Head radius Kopfradius R for electrical loadsbei elektrischer Belastung'''
{| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"
|-
|for für I < 1 A
|R &#8776; 1,5 mm
|-
*'''Failure Probability of Single and Double (Bifurcated) ContactsAusfallwahrscheinlichkeit von Einzel- und Doppelkontakten''' (according to nach Thielecke)
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
|-
!Contact forceKontaktkraft[N] !colspan="42" style="text-align:center"|'''Single contactEinzelkontakt'''!colspan="2" style="text-align:center"|'''Doppelkontakt'''
|-
!
<div class="multiple-images">
<figure id="fig:Failure probability of a contact as a function of the voitage">
[[File:Failure probability of a contact as a function of the voitage.jpg|left|Failure probability of a contact as a function of the voltage Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Spannung (according to nach Kirchdorfer); Ag/Ni10; 10 mA]]
</figure>
<figure id="fig:Failure probability of a contact as a function of the current">
[[File:Failure probability of a contact as a function of the current.jpg|left|Failure probability of a contact as a function of the current Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Stromstärke (according to nach Kirchdorfer); Ag/Ni10; 10 mA; Ag/Ni10; F<sub>k</sub> = 0.45 N; U = 24 V]]
</figure>
</div>
<div class="clear"></div>
<xr id="fig:Failure probability of a contact as a function of the voitage"/><!--Fig. 6.18:--> Failure probability of a contact as a function of the voltage Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Spannung (according to nach Kirchdorfer); Ag/Ni10; 10 mA <xr id="fig:Failure probability of a contact as a function of the current"/><!--Fig. 6.19:--> Failure probability of a contact as a function of the current Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Stromstärke (according to nach Kirchdorfer); Ag/Ni10; F = 0.45 N; U = 24 V10 mA