Difference between revisions of "Faustregeln für die Kontaktdimensionierung"

From Electrical Contacts
Jump to: navigation, search
(temp edit)
 
(German translation)
Line 46: Line 46:
  
  
*'''General Rules for Dimensioning of Contact Rivets'''
+
*'''Faustregeln zur Dimensionierung von Kontaktnieten'''
  
[[File:General Rules for Dimensioning of Contact Rivets.jpg|left|General Rules for Dimensioning of Contact Rivets]]
+
[[File:General Rules for Dimensioning of Contact Rivets.jpg|left|Faustregeln zur Dimensionierung von Kontaktnieten]]
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
 
|-
 
|-
!Dimensioning
+
!Dimensionierung
!Solid Rivets (1)
+
!Massivniet (1)
!Composite Rivets (2)
+
!Bimetallniet (2)
 
|-
 
|-
 
|a : d       
 
|a : d       
Line 77: Line 77:
  
  
*'''Head diameter for electrical loads'''
+
*'''Kopfdurchmesser bei elektrischer Belastung'''
  
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"
 
|-
 
|-
|For AC currents:    
+
|bei Wechselstrom:  
|approx. 1 – 1.5 A/mm²
+
|ca. 1 – 1.5 A/mm²
 
|-
 
|-
|For 1 A   
+
|für 1 A   
|min. 2 mm head diameter
+
|min. 2 mm Kopfdurchmesser
 
|-
 
|-
 
|10 A   
 
|10 A   
|approx. 3 – 3.5 mm head diameter
+
|ca. 3 – 3.5 mm Kopfdurchmesser
 
|-
 
|-
 
|20 A   
 
|20 A   
|approx. 5 mm head diameter
+
|ca. 5 mm Kopfdurchmesser
 
|-
 
|-
|For DC currents:  
+
|bei Gleichstrom:
|approx. 0.5 – 0.8 A/mm²
+
|ca. 0.5 – 0.8 A/mm²
 
|}
 
|}
  
  
*'''Head radius R for electrical loads'''
+
*'''Kopfradius R bei elektrischer Belastung'''
  
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:40%"
 
|-
 
|-
|for I < 1 A     
+
|für I < 1 A     
 
|R &#8776; 1,5 mm
 
|R &#8776; 1,5 mm
 
|-
 
|-
Line 116: Line 116:
  
  
*'''Failure Probability of Single and Double (Bifurcated) Contacts''' (according to Thielecke)
+
*'''Ausfallwahrscheinlichkeit von Einzel- und Doppelkontakten''' (nach Thielecke)
  
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
 
{| class="twocolortable" style="text-align: left; font-size: 12px;width:100%"
 
|-
 
|-
!Contact force[N]     
+
!Kontaktkraft[N]     
!colspan="4" style="text-align:center"|'''Single contact'''
+
!colspan="2" style="text-align:center"|'''Einzelkontakt'''
 +
!colspan="2" style="text-align:center"|'''Doppelkontakt'''
 
|-
 
|-
 
!     
 
!     
Line 157: Line 158:
 
<div class="multiple-images">
 
<div class="multiple-images">
 
<figure id="fig:Failure probability of a contact as a function of the voitage">
 
<figure id="fig:Failure probability of a contact as a function of the voitage">
[[File:Failure probability of a contact as a function of the voitage.jpg|left|Failure probability of a contact as a function of the voltage (according to Kirchdorfer); Ag/Ni10; 10 mA]]
+
[[File:Failure probability of a contact as a function of the voitage.jpg|left|Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Spannung (nach Kirchdorfer); Ag/Ni10; 10 mA]]
 
</figure>
 
</figure>
  
 
<figure id="fig:Failure probability of a contact as a function of the current">
 
<figure id="fig:Failure probability of a contact as a function of the current">
[[File:Failure probability of a contact as a function of the current.jpg|left|Failure probability of a contact as a function of the current (according to Kirchdorfer); Ag/Ni10; F<sub>k</sub> = 0.45 N; U = 24 V]]
+
[[File:Failure probability of a contact as a function of the current.jpg|left|Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Stromstärke (nach Kirchdorfer); Ag/Ni10; 10 mA; Ag/Ni10; F<sub>k</sub> = 0.45 N; U = 24 V]]
 
</figure>
 
</figure>
 
</div>
 
</div>
 
<div class="clear"></div>
 
<div class="clear"></div>
  
<xr id="fig:Failure probability of a contact as a function of the voitage"/><!--Fig. 6.18:--> Failure probability of a contact as a function of the voltage (according to Kirchdorfer); Ag/Ni10; 10 mA
+
<xr id="fig:Failure probability of a contact as a function of the voitage"/><!--Fig. 6.18:--> Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Spannung (nach Kirchdorfer); Ag/Ni10; 10 mA
 
+
<xr id="fig:Failure probability of a contact as a function of the current"/><!--Fig. 6.19:--> Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Stromstärke (nach Kirchdorfer); Ag/Ni10; 10 mA
<xr id="fig:Failure probability of a contact as a function of the current"/><!--Fig. 6.19:--> Failure probability of a contact as a function of the current (according to Kirchdorfer); Ag/Ni10; F = 0.45 N; U = 24 V
 
  
 
==Referenzen==
 
==Referenzen==

Revision as of 22:12, 20 September 2014

Faustregeln für die Kontaktdimensionierung

  • Empfohlene Mindestkontaktkräfte bei leicht reibender Kontaktgabe:
Gold 0.03 N
Silber 0.1 N
Wolfram 0.5 N
  • Richtwerte für Kontaktkräfte:
Signalrelais ≥ 3 cN
Netzrelais ≥ 20 cN
Kfz-Relais ≥ 20 cN
Motorschalter (Schütze)
(Silber-Metalloxid-Kontakte)
0.05 - 0.08 N/A
Leistungsschalter 0.1 - 0.2 N/A
Steckverbinder
(Gold-Beschichtung)
≥ 30 cN/Kontaktstelle
Steckverbinder
(Silber-Beschichtung)
≥ 50 cN/Kontaktstelle
Steckverbinder
(Zinn-Beschichtung)
≥ 1 N/Kontaktstelle


  • Faustregeln zur Dimensionierung von Kontaktnieten
Faustregeln zur Dimensionierung von Kontaktnieten
Dimensionierung Massivniet (1) Bimetallniet (2)
a : d 1.5 : 1 bis 2.5 : 1 2 : 1 bis 2.5 : 1
a : b 2.5 : 1 bis 10 : 1 3 : 1 bis 5 : 1
c : b ≥ 1 : 1 ≥ 1 : 1
b : s ≥ 2 : 1
smin ≈ 0.3 mm


  • Kopfdurchmesser bei elektrischer Belastung
bei Wechselstrom: ca. 1 – 1.5 A/mm²
für 1 A min. 2 mm Kopfdurchmesser
10 A ca. 3 – 3.5 mm Kopfdurchmesser
20 A ca. 5 mm Kopfdurchmesser
bei Gleichstrom: ca. 0.5 – 0.8 A/mm²


  • Kopfradius R bei elektrischer Belastung
für I < 1 A R ≈ 1,5 mm
I = 6 A R ≈ 5 mm
I = 10 A R ≈ 10 mm
I = 20 A R ≈ 15 mm


  • Ausfallwahrscheinlichkeit von Einzel- und Doppelkontakten (nach Thielecke)
Kontaktkraft[N] Einzelkontakt Doppelkontakt
Ag AuNi 5, Pt Ag AuNi 5, Pt
0.04 1 x 10-4 2 x 10-8
0.1 2 x 10-3 4 x 10-5 8 x 10-5 8 x 10-9
0.2 1 x 10-4 8 x 10-6 4 x 10-6 4 x 10-8
0.3 5.5 x 10-6 1.5 x 10-6 1.8 x 10-7 3.2 x 10-10


Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Spannung (nach Kirchdorfer); Ag/Ni10; 10 mA
Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Stromstärke (nach Kirchdorfer); Ag/Ni10; 10 mA; Ag/Ni10; Fk = 0.45 N; U = 24 V

Figure 1 Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Spannung (nach Kirchdorfer); Ag/Ni10; 10 mA Figure 2 Ausfallwahrscheinlichkeit eines Kontaktes in Abhängigkeit von der Stromstärke (nach Kirchdorfer); Ag/Ni10; 10 mA

Referenzen

Referenzen