Switching Contacts
From Electrical Contacts
Revision as of 14:37, 2 December 2022 by Doduco Admin (talk | contribs)
Switching Contacts
- Effects during switching operations
- Influence of out-gasing from plastics
- Influence of corrosive gases on the contact resistance
- Contact Phenomena under the influence of arcing Matertia
- Material transfer
- Arc erosion
- Contact welding

Figure 4: Distribution of cumulative frequency H of the contact resistance for solid contact rivets after 10 days exposure in a three-component test environment with 400 ppb each of H2S, SO2 and NO2 at 25°C, 75% RH; Contact force 10cN; Measuring parameters: ≤ 40 mVDC,10 mA; Probing contact: Gold rivet