General Rules for Dimensioning of Contacts

From Electrical Contacts
Revision as of 10:07, 2 April 2014 by Doduco Redaktion (talk | contribs) (6.4.6 General Rules for Dimensioning of Contacts)

Jump to: navigation, search

6.4.6 General Rules for Dimensioning of Contacts

  • Recommended Minimum Contact Forces at Slightly Sliding

Contact Make:

Gold 0.03 N
Silver 0.1 N
Tungsten 0.5 N
  • Contact Force Recommendations:

Signal relays >3 cN AC power relays > 20 cN Automotive relays > 20 cN Motor switches (Contactors) 0.05 - 0.08 N/A (Silver – Metal oxide contacts) Power switches 0.1 - 0.2 N/A Connectors > 30 cN/contact element (Gold coating) Connectors > 50 cN/contact element (Silver coating) Connectors > 1 N/contact element (Tin coating)

  • General Rules for Dimensioning of Contact Rivets

bild

  • Head diameter for electrical loads

For AC currents: approx. 1 – 1.5 A/mm² For 1 A min. 2 mm head diameter 10 A approx. 3 – 3.5 mm head diameter 20 A approx. 5 mm head diameter For DC currents: approx. 0.5 – 0.8 A/mm²

  • Head radius R for electrical loads

for I < 1 A R 1,5 mm I = 6 A R 5 mm I = 10 A R 10 mm I = 20 A R 15 mm

  • Failure Probability of Single and Double (Bifurcated) Contacts (according to Thielecke)

Fig. 6.18: Failure probability of a contact as a function of the voltage (according to Kirchdorfer); Ag/Ni10; 10 mA

Fig. 6.19: Failure probability of a contact as a function of the current (according to Kirchdorfer); Ag/Ni10; F = 0.45 N; U = 24 V

References

References