Contact Carrier Materials

From Electrical Contacts
Revision as of 15:10, 18 December 2013 by Ermisch (talk | contribs) (5.1.3 High Cu Content Copper Alloys)

Jump to: navigation, search

The reliability and electrical life of contact systems in switching devices as well as in electromechanical and electronic components do not only depend on the contact material. The selection of the most suitable carrier material also plays an important role.

The most frequently used ones are copper based materials. Depending on the application also materials based on nickel or multi-layer composite materials, such as thermo bimetals for example, are frequently used. For special applications in the medium and high voltage technology, as well as for springs and snap discs for the information technology, iron or steel based materials are considered. These are however not included for the purpose of this data book.

Various requirements based on the enduse of the contact components have to be met by carrier materials. Copper materials have to exhibit high electrical and thermal conductivity, good mechanical strength even at elevated temperatures, and in addition a sufficient high resistance against corrosion. If used as springs the carrier materials also must have good elastic spring properties. Besides these, the materials must, depending on the manufacturing processes employed, also have good technological properties like ductility to allow warm and cold forming, suitability for cutting and stamping, and be capable to be welded, brazed or coated by electroplating

5.1 Copper and Copper Alloys

5.1.1 Standards Overview

Copper and copper alloys to be used in electrical and electronic components are usually covered by national and international standards. DIN numbers the materials by a prefix and/or a material number. The newer European standards (EN) refer to the material's usage products and also show a prefix and material number. For reference we also show in table 5.1 the material designation according to UNS, the Unified Numbering System (USA). Other internationally used standard and material numbers include, among others, those issued by CDA (Copper Development Association, USA), and GB (Guo Biao – China).

The most important EN as well as the US based and widely used ASTM standards covering the use of flat rolled copper and copper alloys in electrical contacts are:

Standard Designation D e s c ription
DIN EN 1652 Copper and copper alloys in plate, sheet, strip, and discs for general applications
DIN EN 1654 Copper and copper alloys for springs and connectors
DIN EN 1758 Copper and copper alloys in strip form for system component carriers
ASTM B 103/B103M-10 Spec. for Phosphor Bronce Plate, Sheet, Strip, and Rolled Bar
ASTM B 36/B36M-95 Spec. for Brass Plate, Sheet, Strip, and Rolled Bar
ASTM B 122/B122M-08 Spec. for CuNiSn-, CuNiZn-, and CuNi-Alloy
ASTM B 465-09 Spec. for Copper-Iron-Alloy Plate, Sheet, and Strip
ASTM B 194-08 Standard Spec. for CuBe-Alloy Plate, Sheet, Strip and Rolled Bar
ASTM B 534-07 Sec. for CuCoBe-Alloy and CuNiBe-Alloy Plate, Sheet, Strip, and Rolled Bar

The above DIN EN standards replace in part or completely the older DIN standards DIN 1777, DIN 17670, DIN 1751, DIN 1791.

5.1.2 Pure Copper

Copper is used in electrical engineering mostly because of its high electrical conductivity which with 58 MS/m (or m/Ωmm²) is only slightly below that of silver. Other advantages of copper are its high thermal conductivity, corrosion resistance, and its good ductility. The work hardening properties of ETP copper is illustrated in Figure 1. The increase in strength achieved by cold working can be reversed easily by subsequent annealing. The softening properties are strongly dependent on the preceding cold working percentage (Figure 2 and 5.3).

The purity of technically pure and un-alloyed copper used for electrical applications depends on the type used and ranges between > 99.90 and 99.95 wt%. The copper types are designated mainly by their oxygen content as oxygen containing, oxygen-free, and de-oxidized with phosphorus as described in DIN EN 1652 (Table 1 and 5.2).Tables 5.3. and 5.4 show the physical and mechanical properties of these copper materials. According to these, Cu-ETP, Cu-OFE, and Cu-HCP are the types of copper for which minimum values for the electrical conductivity are guaranteed. Cu-ETP is less suitable for welding or for brazing in reducing atmosphere because of the oxygen content (danger of hydrogen embrittlement). Cu-HCP, Cu-DLP, and Cu-DHP are oxygen free copper types de-oxidized with different phosphorus contents. With increasing phosphorus content the electrical conductivity decreases. Cu-OFE, also called OFHC copper, is free of oxygen and also free of de-oxidizing compounds.

  • ) As units for electrical conductivity MS/m and m/Ω.mm² are commonly used. Frequently – and

mostly in North America – the % IACS value (International Annealed Copper Standard) is also used, 2 where 100% is equivalent to 58 MS/m or m/Ωmm .For the description of mechanical strength 2 properties the units of N/mm or MPa are most commonly used: 2 1 MS/m = 1 m/Ωmm 2 1 MPa = 1 N/mm 5.1.2 Pure Copper

ASTM B 534-07 Sec. for CuCoBe-Alloy and CuNiBe-Alloy Plate, Sheet, Strip, and Rolled Bar
Table 5.1: Material Designations of Some Copper Types
Figure 1: Strain_hardening of Cu-ETP by cold working
Figure 2: Softening of Cu-ETP after annealing for 3hrs after 25% cold working


Tab 5.2

Table 5.3: Physical Properties of Some Copper Types

Table 5.4: Mechanical Properties of Some Copper Types

Fig. 5.1: Strain hardening of Cu-ETP by cold working

Fig. 5.2: Softening of Cu-ETP after annealing for 3hrs after 25% cold working

Fig. 5.3: Softening of Cu-ETP after annealing for 3hrs after 50% cold working

5.1.3 High Cu Content Copper Alloys

The high Cu content alloy materials are closest in their properties to pure copper materials. By defined addition of small amounts of alloying elements it is possible to increase the mechanical strength and especially the softening temperature of copper and at the same time decrease the electrical conductivity only insignificantly (Fig. 5.4). Silver, iron, tin, zinc, nickel, chromium, zirconium, silicon, and titanium are used. Usually the additive amounts are significantly below 3 wt%. This group of materials consists of mixed crystal as well as precipitation hardening alloys. The precipiytion hardening copper-beryllium and copper-chromium-zirconium materials are decribed later in a separate section.

From the large number of high-Cu alloys only the properties of selected ones are covered here (Tables 5.5 and 5.6). Some of these materials are not included in the EN standards system.

The low alloyed materials CuAg0.1 and CuCd1 are mostly used as overhead drive cables where they have to meet sustained loads at elevated temperatures without softening.

The materials CuFe0.1 and CuSn0.15 have a high electrical conductivity. The mechanical strength of both is relatively low but stays almost constant at temperatures up to 400°C. The are used as substrates for power semiconductors and also as carriers for stationary contacts in higher energy switchgear.

CuFe2 is a material exhibiting high electrical conductivity and good formability. During an annealing process Fe-rich precipitations are formed in the " -Cu matrix which change the mechanical properties very little but increase the electrical conductivity significantly. Besides being used as a contact carrier material in switching devices, this material has broader applications in automotive connectors and as a substrate in the semiconductor technology.

CuNi2Si has high mechanical strength, good formability, and at the same time high electrical conductivity. This combination of advantageous properties is achieved by a defined finely dispersed precipitation of nickel silicides. CuNi2Si is used mainly in the form of stamped and formed parts in thermally stressed electromechanical components for automotive applications.

CuSn1CrNiTi and CuCrSiTi are advanced developments of the Cu-Cr-Ti precipitation materials with fine intermetallic dispersions. The material CuNi1Co1Si also belongs into this family and has properties similar to the low alloyed CuBe materials.

Tab. 5.5 Physical Properties of Selected High Cu Content Copper Alloys (2 teile!)

Table 5.6; Mechanical Properties of Selected High Cu Content Copper Alloys (2 teile!)

These newer copper based materials optimize properties such as electrical conductivity, mechanical strength, and relaxation, which are custom tailored to specific applications. Typical uses include contact springs for relays, switches, and connectors.

Fig. 5.4: Influence of small additions on the electrical conductivity of copper

5.1.4 Naturally Hard Copper Alloys